- New





RLX COMPONENTS s.r.o. , Electronic Components Distributor.
RLX COMPONENTS s.r.o. , Electronic Components Distributor.
Industrial 8-Ch Analog Acquisition Module, 12-bit High-precision, current mode 0~20mA (WS-25821)
Industrial 8-Ch Analog Acquisition Module, 12-bit High-precision, current mode 0~20mA
12-bit High-precision
Supports Voltage and Current Acquisition
DC 7~36V Wide Voltage
Modbus RTU Protocol
Multiple Isolation Protection

Modbus RTU Analog Input 8CH is an industrial standard analog acquisition module, supports multiple ranges and 8-ch simultaneous acquisition. Adopts Modbus RTU protocol with built-in protection circuits such as power isolation, magnetical isolation, resettable fuse, and TVS.
Modbus RTU Analog Input 8CH
Supports four ranges (configurable):
0~5V/1~5V
0~20mA (default) /4~20mA
Modbus RTU Analog Input 8CH (B)
Supports four ranges (configurable):
0~10V (default)/2~10V
0~20mA /4~20mA
| MODEL | Modbus RTU Analog Input 8CH | Modbus RTU Analog Input 8CH (B) |
|---|---|---|
| COMMUNICATION INTERFACE | RS485 | |
| BAUD RATE | 4800, 9600, 19200, 38400, 57600, 115200, 128000, 256000 | |
| DEFAULT COMMUNICATION FORMAT | 9600, N, 8, 1 | |
| MODBUS PROTOCOL | Standard Modbus RTU protocol | |
| POWER SUPPLY | DC 7~36V | |
| SAMPLING ACCURACY | 12-bit resolution, accuracy ≤3% | |
| DATA UPDATE RATE | 25Hz | |
| INPUT MODE | supports single-ended/differential input, supports voltage and current simultaneous acquisition | |
| DEFAULT MODE | 8-ch current mode, 0~20mA | 8-ch voltage mode, 0~10V |
| RANGE | 0~5V/1~5V 0~20mA/4~20mA |
0~10V/2~10V 0~20mA/4~20mA |
| CURRENT SAMPLING RESISTOR | 249Ω | 499Ω |
Supports Sending Modbus RTU Protocol Commands Via RS485
To Acquire Data From 0~20mA/0~10V Sensor

Onboard power and signal dual isolation for RS485 communication, provides stable isolation voltage, features high reliability and strong anti-interference performance. Built-in TVS (transient voltage suppression tube) can effectively suppress the surge voltage and transient peak voltage in the circuit, lightningproof & ESD protection. Built-in resettable fuse and protection diode to ensure stable current and voltage output, provides over-current and over-voltage proof, improves shock-proof performance, suitable for the industrial environments with high requirement.

8-Ch Analog Acquisition Interfaces, Voltage And Current Acquisition Is Switchable Via Jumper. Multiple Ranges Configurable Via Software


Supports Setting Device Address (1~255) For Multi-Device Cascading, Supports Single-Ended/Differential Input, Supports Voltage And Current Simultaneous Acquisition

Built-In Fuse And Anti-Reverse Protection, With ESD Protection For Analog Input

Supports 35mm Standard Guide Rail, With Rail-Mount Buckle, Easy To Install.




Balenie Obsahuje / Package Content