RLX COMPONENTS s.r.o. , Electronic Components Distributor.
RLX COMPONENTS s.r.o. , Electronic Components Distributor.
UPS3 Uninterrupted Power Supply (G146068525665) for ODROID-C1 / C1+ / C2
The UPS3 is designed specifically for the ODROID-C1 / C1+ / C2.
Uninterrupted Power Supply is an electrical apparatus that provides emergency power to a load when the input power source, typically mains power, fails. The on-battery runtime of most uninterruptible power sources is relatively short but sufficient to start a standby power source or properly shut down the ODROID. It is equipped with a rechargeable 3,000mAh Lithium Polymer battery and a charger with a booster IC for 5V output. When the AC power source fails, the UPS3 keeps supplying the power to the ODROID-C1/C1+/C2 with the battery. There is a digital output pin to notice the battery low-level warning to the ODROIDs to trigger the shutdown process. And the AC power source available, UPS3 will supply the power to the ODROID board again automatically. It will significantly reduce the risk of data loss by sudden power-down.
Thanks to the 40pin connector with long pins, you can stack an add-on board on the UPS3.
Full guide, schematics, PCB layout file and detail information is
on our WiKi : https://wiki.odroid.com/accessory/power_supply_battery/odroid-ups3
Software update is required.
PACKAGE INCLUDES :
– 3000mAh battery pack
– UPS Board
– 2 x 11mm PCB spacer (metal)
– 4 x 5mm screw (metal)
5V/2A Power Supply is sold separately.
BOARD DETAIL :
DC Input Voltage / Current | DC 4.8V ~ 5.4V / 2A minimum |
Battery Charging Time / Current | 1.5 ~ 2 Hours / 2A maximum |
DC Output Current / Voltage | Maximum 2A / 5V |
Battery Pack | 3,000mAh Lithium Polymer |
Connector : Molex 51021-0200 | |
Battery Life Cycle | Carry out 400 cycle charging / discharging @ 20±5℃ |
Integrated Protection PCB | Over charge and discharge protection |
Estimated Running Time | 2-4 hours with typical load of 300mA @ 5V |