FLUKE 115 + 1AC-II VoltAlert voltage detector + C90 soft case
      FLUKE 115 + 1AC-II VoltAlert voltage detector + C90 soft case
      FLUKE 115 + 1AC-II VoltAlert voltage detector + C90 soft case

      FLUKE 115 + 1AC-II VoltAlert voltage detector + C90 soft case

      FLUKE 115

      FLUKE 115 + 1AC-II VoltAlert voltage detector + C90 soft case

      Množstvo:

      FLUKE 115 + 1AC-II VoltAlert voltage detector + C90 soft case

      For general purpose electrical and electronic test requirements, the Fluke 115 true-rms digital multimeter provides the perfect answer. Its simple operation, compact design and ease of use makes it perfect for quick verifications and field service use. The Fluke 115 displays true-rms voltage and current readings with 6000 count resolution, tests diodes, frequency, continuity and capacitance and provides Min/Max/Average readings to record signal fluctuations. A large white LED backlight aids work in poorly lit areas. Its easy-open battery access door makes battery changes a snap. Fluke 115 multimeters are independently tested for safe use in CAT III 600V environments. 

      • Large white LED backlight to work in poorly lit areas
      • Resistance and continuity
      • Frequency and capacitance
      • Maximum Voltage ac/dc 600V
      • 10A ac/dc current measurement (20 A overload for 30-seconds max)
      • Min/Max/Average to record signal fluctuations
      • CAT III 600 V safety rated
      • More Informations

       

      Specifications
      Maximum voltage between any terminal and earth ground
         600 V
      Surge protection
         6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
      Display
      Digital:  6,000 counts, updates 4 per second
      Bar graph
         33 segments, updates 32 per second
      Operating Temperature
         -10 °C to + 50 °C
      Storage Temperature
         -40 °C to + 60 °C
      Battery type
         9 volt Alkaline, NEDA 1604A/ IEC 6LR61
      Battery Life
         400 hours typical, without backlight

       

      Accuracy Specifications
      DC millivolts
      Range:  600.0 mV
      Resolution:  0.1 mV
      Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
      DC volts
      Range/Resolution:  6.000 V / 0.001 V
      Range/Resolution:  60.00 V / 0.01 V
      Range/Resolution:  600.00 V / 0.1 V
      Accuracy:  ± ([% of reading] + [counts]): 0.5% + 2
      AC millivolts1 true-rms
      Range:  600.0 mV
      Resolution:  0.1 mV
      Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
      AC volts1 true-rms
      Range/Resolution:  6.000 V / 0.001 V
      Range/Resolution:  60.00 V / 0.01 V
      Range/Resolution:  600.0 V / 0.1 V
      Accuracy:  1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz)
      Continuity
      Range:  600 Ω
      Resolution:  1 Ω
      Accuracy:  Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer.
      Ohms
      Range/Resolution:  600.0 Ω / 0.1 Ω
      Range/Resolution:  6.000 kΩ / 0.001 kΩ
      Range/Resolution:  60.00 kΩ / 0.01 kΩ
      Range/Resolution:  600.0 kΩ / 0.1 kΩ
      Range/Resolution:  6.000 MΩ / 0.001 MΩ
      Accuracy:  0.9 % + 1
      Range/Resolution:  40.00 MΩ / 0.01 MΩ
      Accuracy:  5 % + 2
      Diode Test
      Range/Resolution:  2.00 V / 0.001 V
      Accuracy:  0.9% + 2
      Capacitance
      Range/Resolution:  1000 nF / 1 nF
      Range/Resolution:  10.00 µF / 0.01 µF
      Range/Resolution:  100.0 µF / 0.1 µF
      Range/Resolution:  9999 µF / 1 µF
      Range/Resolution:  100 µF to 1000 µF
      Accuracy:  1.9% + 2
      Range/Resolution:  > 1000 µF
      Accuracy:  5% + 20%
      Lo-Z Capacitance
      Range:  1 nF to 500 µF
      Accuracy:  10% + 2 typical
      AC amps true-rms (45 Hz to 500Hz)
      Range/Resolution:  6.000 A / 0.001 A
      Range/Resolution:  10.00 A / 0.01 A
      Accuracy:  1.5% + 3
         20 A overload for 30-seconds max
      DC amps
      Range/Resolution:  6.000 A / 0.001 A
      Range/Resolution:  10.00 A / 0.01 A
      Accuracy:  1.0% + 3
         20 A overload for 30-seconds max
      Hz (V or A input)2
      Range/Resolution:  99.99 Hz / 0.01 Hz
      Range/Resolution:  999.9 Hz / 0.01 Hz
      Range/Resolution:  9.999 kHz / 0.001 kHz
      Range/Resolution:  50 kHz / 0.01 kHz
      Accuracy:  0.1% + 2